Double-chamber single-phase transformers with standard EI shape lamination with composite core are produced in accordance with ČSN EN 61 558 in any voltage transfer combination between 1 – 1 000 V, frequency 50/60 Hz, covering IP00, isolation class B and maximum ambient temperature 40 °C. Their sizes and rated outputs are shown in the table.
Different options are possible according to customer’s demand. For example: screening, higher temperature class, or ambient temperature, fuse on primary or secondary side etc. The power network voltage may vary ±10%, this should be considered to transformer power rating designation.
Design:
Type | Design | Dimensions [mm] | Rated output [VA] | Weight [kg] | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
A | B1 | B2 | C1 | C2 | D | E | F | ||||
E1616 | ZU | 65 | 50 | — | 36 | — | 60 | v ose | 3,6 | 8 | 0,26 |
E1620 | ZU | 65 | 50 | — | 43 | — | 60 | v ose | 3,6 | 10 | 0,32 |
E2020 | VO, PJ | 57 | — | 46 | — | 63 | 29 | 35 | 4,8 | 12 | 0,46 |
E2025 | VO, PJ | 57 | — | 51 | — | 63 | 29 | 40 | 4,8 | 20 | 0,60 |
E2030 | VO, PJ | 57 | — | 56 | — | 63 | 29 | 45 | 4,8 | 30 | 0,70 |
E2520 | VO, PJ | 64 | — | 50 | — | 79 | 50 | 37 | 4,8×6,8 | 25 | 1,00 |
E2525 | VO, PJ | 64 | — | 55 | — | 79 | 50 | 42 | 4,8×6,8 | 32 | 1,10 |
E2532 | VO, PJ | 64 | — | 62 | — | 79 | 50 | 49 | 4,8×6,8 | 50 | 1,30 |
E2540 | VO, PJ | 64 | — | 70 | — | 79 | 50 | 57 | 4,8×6,8 | 60 | 1,40 |
E3236 | VO, PJ | 81 | — | 71 | — | 102 | 64 | 54 | 5,2×8 | 100 | 2,30 |
E3246 | VO, PJ | 81 | — | 82 | — | 102 | 64 | 64 | 5,2×8 | 115 | 2,70 |
E3260 | VO, PJ | 81 | — | 96 | — | 102 | 64 | 78 | 5,2×8 | 130 | 3,10 |